Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiol ; 406: 131997, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556216

RESUMEN

AIMS: Myocardial bridging (MB) is a frequent congenital anomaly of the epicardial coronary arteries commonly considered a benign condition. However, in some cases a complex interplay between anatomical, clinical and physiology factors may lead to adverse events, including sudden cardiac death. Coronary CT angiography (CCTA) emerged as the gold standard noninvasive imaging technique for the evaluation of MB. Aim of the study was to evaluate MB prevalence and anatomical features in a large population of patients who underwent CCTA for suspected CAD and to identify potential anatomical and clinical predictors of adverse cardiac events at long-term follow-up. METHODS AND RESULTS: Two-hundred and six patients (mean age 60.3 ± 11.8 years, 128 male) with MB diagnosed at CCTA were considered. A long MB was defined as ≥25 mm of overlying myocardium, whereas a deep MB as ≥2 mm of overlying myocardium. The study endpoint was the sum of the following adverse events: cardiac death, bridge-related acute coronary syndrome, hospitalization for angina or bridge-related ventricular arrhythmias and MB surgical treatment. Of the 206 patients enrolled in the study, 9 were lost to follow-up, whereas 197 (95.6%) had complete follow-up (mean 7.01 ± 3.0 years) and formed the analytic population. Nineteen bridge-related events occurred in 18 patients (acute coronary syndrome in 7, MB surgical treatment in 2 and hospitalization for bridge-related events in 10). Typical angina at the time of diagnosis and long MB resulted as significant independent predictors of adverse outcome. CONCLUSIONS: Typical angina and MB length ≥ 25 mm were independent predictors of cardiac events.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Puente Miocárdico , Valor Predictivo de las Pruebas , Humanos , Masculino , Puente Miocárdico/diagnóstico por imagen , Puente Miocárdico/complicaciones , Puente Miocárdico/epidemiología , Femenino , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Anciano , Estudios de Seguimiento , Angiografía Coronaria/métodos , Estudios Retrospectivos
2.
J Clin Med ; 12(22)2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38002733

RESUMEN

Mitral valve regurgitation (MR) is a multifaceted valvular heart disease. Echocardiography plays a central role in etiology assessment, severity quantification, treatment candidacy, outcome evaluation, and patient follow-up. In this review, we describe the comprehensive echocardiographic assessment of MR, including transthoracic (TTE) and transesophageal (TEE) approaches, 2D and 3D modalities, strain imaging, stress echocardiography, and artificial intelligence (AI) applications. Transcatheter edge-to-edge mitral valve repair (TEER) has been established as a key therapy for patients with severe, symptomatic MR and high surgical risk. TEER is performed under TEE guidance. We outline a practical overview of echocardiographic guidance on TEER.

3.
J Cardiovasc Dev Dis ; 9(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35050222

RESUMEN

Prosthetic valve (PV) dysfunction (PVD) is a complication of mechanical or biological PV. Etiologic mechanisms associated with PVD include fibrotic pannus ingrowth, thrombosis, structural valve degeneration, and endocarditis resulting in different grades of obstruction and/or regurgitation. PVD can be life threatening and often challenging to diagnose due to the similarities between the clinical presentations of different causes. Nevertheless, identifying the cause of PVD is critical to treatment administration (thrombolysis, surgery, or percutaneous procedure). In this report, we review the role of multimodality imaging in the diagnosis of PVD. Specifically, this review discusses the characteristics of advanced imaging modalities underlying the importance of an integrated approach including 2D/3D transthoracic and transesophageal echocardiography, fluoroscopy, and computed tomography. In this scenario, it is critical to understand the strengths and weaknesses of each modality according to the suspected cause of PVD. In conclusion, for patients with suspected or known PVD, this stepwise imaging approach may lead to a simplified, more rapid, accurate and specific workflow and management.

4.
J Clin Med ; 10(21)2021 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-34768549

RESUMEN

We aimed to evaluate the feasibility and accuracy of machine learning-based automated dynamic quantification of left ventricular (LV) and left atrial (LA) volumes in an unselected population. We enrolled 600 unselected patients (12% in atrial fibrillation) clinically referred for transthoracic echocardiography (2DTTE), who also underwent 3D echocardiography (3DE) imaging. LV ejection fraction (EF), LV, and LA volumes were obtained from 2D images; 3D images were analyzed using dynamic heart model (DHM) software (Philips) resulting in LV and LA volume-time curves. A subgroup of 140 patients also underwent cardiac magnetic resonance (CMR) imaging. Average time of analysis, feasibility, and image quality were recorded, and results were compared between 2DTTE, DHM, and CMR. The use of DHM was feasible in 522/600 cases (87%). When feasible, the boundary position was considered accurate in 335/522 patients (64%), while major (n = 38) or minor (n = 149) border corrections were needed. The overall time required for DHM datasets was approximately 40 seconds. As expected, DHM LV volumes were larger than 2D ones (end-diastolic volume: 173 ± 64 vs. 142 ± 58 mL, respectively), while no differences were found for LV EF and LA volumes (EF: 55% ± 12 vs. 56% ± 14; LA volume 89 ± 36 vs. 89 ± 38 mL, respectively). The comparison between DHM and CMR values showed a high correlation for LV volumes (r = 0.70 and r = 0.82, p < 0.001 for end-diastolic and end-systolic volume, respectively) and an excellent correlation for EF (r = 0.82, p < 0.001) and LA volumes. The DHM software is feasible, accurate, and quick in a large series of unselected patients, including those with suboptimal 2D images or in atrial fibrillation.

5.
Acta Biomed ; 91(4): e2020167, 2020 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-33525224

RESUMEN

The Covid-19 pandemic has been the most defining event of our era. The world of healthcare has experienced first-hand the dramatic situation of treating patients in the face of the dangers of contagion and limited resources. Difficult choices have everywhere been made alongside ethical reflection. Now that, at least in our part of the world, viral infection seems to be broadly on the decline, there is an urgent need for fresh, anthropological, ethical reflection. It is important to avoid being unprepared in the event of further occasions, but above all, to now think in global terms. This is because the pandemic has forced us to recognise the urgency of building alliance in healthcare and a balanced relationship with the environment.


Asunto(s)
COVID-19 , Ética Médica , Humanismo , Discusiones Bioéticas , Predicción , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...